VIDOS-NVR
RAID-5 data storage unit
- SATA single controller
RAID subsystem with 4Gbps Fibre Channel host I/F
providing full-featured RAID functionality
- Auto switch cache policy
and auto shutdown
- Support for up to 1GB
cache memory
- Intelligent drive
handling
Specifications
RAID
Multiple arrays configurable
with dedicated or global hot spares
RAID levels supported: RAID 0,
1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID and JBOD
Online expansion by
- Adding new drives
- Copying and replacing
drives with drives of larger capacity
Automatic background rebuild
Configurable stripe size and
write policy per array
Intelligent drive handling:
- In degraded mode: skips
irreparable blocks to continue rebuild
- In normal operation:
data-block verification and repair
Host Interface
2 x 4Gbps Fibre Channel
Concurrent I/O commands
Tagged command queuing up to
256
Variable stripe size per
logical drive
Optimization setting for
random or sequential I/Os
Drive Interface (depending
on model)
Eight (8) / Twelve (12) /
Sixteen (16) / Twenty Four (24) 3Gbps SATA, hot-swappable drive
trays that accommodate 1-inch pitch, 3.5-inch
SATA disk drives
8/12/16/24 hot-swappable drive
trays
Automatic bad-sector
reassignment
Dedicated bandwidth to each
connected drive
Management
Front LCD control panel for
setup and configuration
10/100 BaseT Ethernet for
out-of-band management
RS-232C for local access to
firmware-embedded utility
Firmware-embedded Java-based
RAIDWatch™ GUI manager
- VT-100 terminal emulation
via RS-232C
- Telnet access via onboard
Ethernet port
- Cross-platform, remote
administration with SSL
- Out-of-band access via
Ethernet (GUI-onboard)
- Centralized management to
monitor and administer multiple RAID units
on one screen
SNMP agent support:
- SNMP trap event
notification with plain-text event message
(no MIB file required)
- SNMP V2.0 MIB file
support with get-and-set commands
Indicators
Onboard alarm is triggered
when one of the following modules fails:
- RAID controller module
- Cooling module
- Power supply unit
- Hard drive
Notification Processing Center
(NPC) for real-time event notification over
email, LAN broadcast, or SNMP traps
Module status LED indicators:
- Two (2) per drive tray
- Two (2) per cooling
module
- One (1) per power supply
unit
- Three (3) per LCD panel
- Six (6) per RAID
controller module
Auto switch cache policy
and Auto shutdown
When a RAID controller detects
conditions exceeding preset thresholds, the
following actions will be exerted to protect the
hardware:
- Cached data is
automatically flushed and the array’s
caching mode switches from write-back to
write-through mode.
- If conditions persist
past the preset period of time, auto
shutdown of the controller will commence.
All thresholds associated with
this mechanism are user configurable and, once a
subsystem manager restores the normal operating
conditions, the caching mode changes from
write-through back to write-back mode.
Intelligent Drive Handling
If two bad blocks occur on two
member drives of an array, the integrity of the
stored data is endangered. Media Scan, the
innovative intelligent drive handling function,
retrieves data from the damaged sectors. Media
Scan handles low quality drives in both the
degraded mode and during the rebuild process.
For additional data security, other intelligent
drive management features include the
transparent resetting of hung hard drives,
power-failure management, and bad-drive handling
during LD expansion.
Physical/Electrical
Power supply:
Two (2) redundant
hot-swappable power supplies with PFC
Input: 90~260VAC, 47~63Hz
Output: (Maximum output: 460
Watts)
+12.0V 38A max
+ 5.0V 25A max.
+ 3.3V 20A max.
Dimensions: 265D x 107W x
42.2H mm
Cooling fan
Two (2) redundant cooling fan
modules
Environmental Specification
Operating temperature: 0~40°C
Non-operating temperature: -20 to 60°C
Relative humidity: 5~95%, non-condensing
Operating altitude:
- Operating: 0~12,000 ft
- Non-operating: 0~20,000 ft
Dimensions:
8/12 Bay unit
2U enclosure: 88H x 446.2W x 486.5D mm
2U enclosure with protrusions: 88H x 481.2W x
525D mm
Package: 344H x 600W x 670D mm
16 Bay unit
3U enclosure: 131H x 446.2W x 500D mm
3U enclosure with protrusions: 131H x 485W x
535D mm
Package: 476H x 592W x 695D mm
System weight (w/o drives):
8/12 Bay unit
Net weight: 16kg
Gross weight:23.5kg
16 Bay unit
Net weight: 24kg
Gross weight:32.5kg
SLD
Security & Communications
The Old Forge, Ockham Lane
Ockham, Surrey
GU23 6PH
England
Tel: +44.1483225633
Fax: +44.1483225634
|